RAYPODO firmware upgrade support center for Android PoE tablets and commercial touch displays

RAYPODO firmware upgrade support is available for selected Android PoE tablets, wall mount Android tablets, industrial Android tablets, and commercial touchscreen devices.

Please note that RAYPODO firmware is not universal. Different screen sizes, CPU platforms, Android versions, memory configurations, hardware revisions, LCD panels, touch panels, network modules, and production batches may require different firmware packages.

Before downloading or upgrading firmware, customers must confirm the product serial number on the back label and contact RAYPODO sales or support for the correct firmware guidance.


Important Notice Before Firmware Upgrade

Firmware packages are model-specific and batch-specific. Please do not download or flash firmware without confirmation from RAYPODO sales or support.

The firmware may be different depending on the product size, CPU model, Android version, RAM, storage, screen panel, touch driver, Ethernet configuration, Wi-Fi module, and hardware revision.

Using the wrong firmware may cause boot failure, black screen, display abnormality, touchscreen failure, Ethernet failure, Wi-Fi issues, system crash, or the device becoming unusable.

Before upgrading firmware, please check the serial number on the back of the product and contact your RAYPODO sales representative or support team for confirmation. Firmware packages are not publicly listed on this page. To prevent incorrect firmware installation and device failure, RAYPODO provides firmware download links only after confirming the product serial number, hardware configuration, and back label photo.


Why Firmware Must Be Confirmed Before Download

RAYPODO commercial Android devices are built for fixed installation and 24/7 commercial use. Unlike consumer tablets or smartphones, firmware cannot always be selected only by screen size or Android version.

For example, an 8-inch Android PoE tablet, 10.1-inch Android PoE tablet, 13.3-inch Android tablet, 15.6-inch Android tablet, 18.5-inch Android tablet, 21.5-inch Android wall mount tablet, 23.8-inch Android touchscreen display, 24-inch Android wall mount tablet, 27-inch Android touchscreen display, and 32-inch Android touchscreen display may use different firmware packages even if they look similar from the outside.

Even products with the same screen size may use different CPU platforms, Android versions, LCD panels, touch ICs, network modules, or hardware revisions. Therefore, customers should always confirm the serial number and product label before downloading firmware.

Item to ConfirmWhy It Matters
Product size8, 10.1, 13.3, 15.6, 18.5, 21.5, 23.8, 24, 27, and 32 inch devices may use different firmware.
CPU platformRK3288, RK3566, RK3568, RK3576S, RK3576, RK3588, and other platforms require different firmware packages.
Android versionAndroid 8.1, Android 10, Android 11, Android 12, Android 13, and Android 14 firmware cannot be mixed.
RAM and storageDifferent memory configurations may require different firmware settings.
Serial numberThe serial number helps RAYPODO confirm the production batch and hardware revision.
Back label photoThe label helps confirm the exact product model before firmware is provided.
Hardware revisionDisplay, touch, Ethernet, Wi-Fi, and other drivers may vary between batches.

RAYPODO Android tablet firmware upgrade process using DriverAssistant and RKDevTool
  1. Check the product label on the back of the device.
  2. Record the product size, CPU model, Android version, RAM, storage, SN number, and MAC address.
  3. Contact RAYPODO sales or support before downloading any firmware package.
  4. RAYPODO will confirm the correct firmware according to the product serial number and hardware configuration.
  5. Download the firmware package only from the link provided by RAYPODO sales or support.
  6. Prepare the correct USB data cable and confirm the correct upgrade port for your CPU platform.
  7. Use the RKDevTool version provided by RAYPODO together with the firmware package.
  8. Follow the corresponding upgrade guide and use the correct upgrade tool.
  9. If the device cannot enter loader mode or cannot be detected by the tool, stop the operation and contact RAYPODO support.

Please do not flash firmware from another product, another order, another screen size, another Android version, another production batch, or another RKDevTool version without confirmation.


Supported Product Sizes

RAYPODO firmware upgrade support may apply to selected products in the following sizes:

  • 8-inch Android PoE tablet
  • 10.1-inch Android PoE tablet
  • 13.3-inch Android tablet
  • 15.6-inch Android tablet
  • 18.5-inch Android tablet
  • 21.5-inch Android wall mount tablet
  • 23.8-inch Android touchscreen display
  • 24-inch Android wall mount tablet
  • 27-inch Android touchscreen display
  • 32-inch Android touchscreen display

Because different hardware configurations may exist under the same size, please always confirm the serial number before downloading firmware.


Upgrade Cable and Port Requirements

Before starting a firmware upgrade, please confirm the correct USB data cable and the correct upgrade port for your CPU platform. Using the wrong cable or the wrong port is the most common reason why the upgrade tool cannot detect the device.

CPU PlatformFirmware Upgrade CableUpgrade Port on the Device
RK3288USB-A to USB-A data cableUSB OTG port beside the DC power port
RK3566USB-A to USB-A data cableUSB OTG port beside the DC power port
RK3568USB-A to USB-A data cableUSB OTG port beside the DC power port
RK3576SUSB-A to USB-A data cableUSB OTG port beside the DC power port
RK3576USB-A to USB-C data cableThe Type-C port on the device. This port is the USB OTG upgrade port.
RK3588USB-A to USB-C data cableThe Type-C port on the device. This port is the USB OTG upgrade port.

Important: Use a USB data cable, not a charging-only cable. A charging-only cable cannot transfer data and the upgrade tool will not detect the device.

RK3576 and RK3588 Devices

RK3576 and RK3588 devices do not have a separate USB-A OTG port. Connect the USB-A end of the cable to the computer and the USB-C end to the Type-C port of the RAYPODO device. On these models the Type-C port is the USB OTG upgrade port. Please note that RK3576S is different from RK3576: the RK3576S platform uses a USB-A to USB-A data cable connected to the USB OTG port beside the DC power port.

USB-A to USB-C data cable required for RK3576 and RK3588 Android tablet firmware upgrade
USB-A to USB-C data cable used for RK3576 and RK3588 firmware upgrade.
Type-C USB OTG firmware upgrade port on a RAYPODO Android all in one PC marked with a red arrow
The Type-C port marked by the red arrow is the USB OTG upgrade port. Do not use the USB-A ports, HDMI port, or RJ45 port for firmware upgrade.

The exact position of the Type-C port varies by product model. On most RAYPODO devices it is located in the rear interface area, between the HDMI port and the USB-A ports. If you are not sure which port to use, please send a photo of the interface area to RAYPODO technical support for confirmation before starting the upgrade.


Firmware Upgrade Guides and Tools

The RAYPODO Firmware Upgrade SOP is updated as new CPU platforms and upgrade methods are added. Version 1.3, released in September 2026, is the current version and replaces all earlier versions. It covers RK3288, RK3566, RK3568, RK3576S, RK3576, and RK3588, and adds the USB cable and upgrade port requirements for each platform, the RKDevTool version reference, and the Rockchip Linux Upgrade Tool. If you downloaded an earlier version of this document, please download version 1.3 before starting a firmware upgrade, as the cable and port requirements for RK3576 and RK3588 were added in this version.

Download RAYPODO Firmware Upgrade SOP PDF (V1.3, September 2026) PDF

RAYPODO Firmware Upgrade SOP V1.3 (September 2026) — alternate download link PDF

The following documents and tools are provided for firmware upgrade preparation. The correct firmware package and the required RKDevTool version will be confirmed separately by RAYPODO sales or support according to the product serial number, CPU platform, Android version, and hardware configuration.

Please note that RKDevTool is not universal for all firmware packages. Different Android versions, CPU platforms, and special firmware builds may require different RKDevTool versions. Please do not use a random or newer RKDevTool version without confirmation from RAYPODO.

ResourceDescriptionAction
Upgrade Tools & GuidesRKDevTool for Windows (multiple versions), the DriverAssistant driver tool, the Rockchip Linux Upgrade Tool (upgrade_tool) for Linux hosts, the per-platform upgrade guides, and the README — all provided together in one folder. Use only the tool version confirmed by RAYPODO for your firmware.Open Download Folder
Firmware Upgrade SOP PDF (V1.3)Official RAYPODO firmware upgrade SOP, version 1.3, September 2026. Covers RK3288, RK3566, RK3568, RK3576S, RK3576, and RK3588, including the updated cable and upgrade port requirements, the RKDevTool version reference, and the Linux upgrade tool.Download SOP PDF | Mirror
Firmware PackageFirmware is not publicly listed. It is provided only after RAYPODO confirms your serial number, hardware configuration, and back label photo.Request Firmware Access

RKDevTool Version Reference

The RKDevTool version must match the firmware package. The following table is for reference only. Please follow the tool version provided by RAYPODO sales or support together with the firmware package.

Firmware / PlatformRecommended RKDevTool VersionImportant Note
Android 11 firmwareRKDevTool v2.84Commonly used for selected Android 11 firmware packages.
RK3566 / RK3568 Android 13 firmwareRKDevTool v3.13Used for selected RK3566 and RK3568 Android 13 firmware packages.
RK3576S firmwareRKDevTool v3.28Used for selected RK3576S Android 14 firmware packages, including the 10.1-inch RK3576S PoE tablet.
RK3576 firmwareRKDevTool v3.28Used for selected RK3576 firmware packages.
RK3588 firmwareRKDevTool v2.93Used for selected RK3588 Android firmware packages.
Special firmware versionRKDevTool v3.30Only use this version when RAYPODO specifically provides it for a special firmware package.

Please install DriverAssistant first, then open the correct RKDevTool version. If you are not sure which RKDevTool version should be used, please stop the upgrade process and contact RAYPODO support before flashing firmware.

Using the wrong RKDevTool version or flashing the wrong firmware may cause upgrade failure, boot failure, black screen, touchscreen failure, Ethernet or Wi-Fi issues, system crash, or the device becoming unusable.

Upgrade Tools for Windows and Linux

More than one upgrade tool is available. The correct tool and tool version depend on the CPU platform, the Android version, and the firmware build.

Host SystemToolDescription
WindowsRockchip RKDevTool with DriverAssistantStandard method described in the RAYPODO firmware upgrade SOP. Multiple versions exist and they are not fully compatible with each other.
LinuxRockchip Linux Upgrade Tool (upgrade_tool, command line)Used when the customer works on a Linux host or in an automated production environment. Provided by RAYPODO on request.

Firmware packages are provided only after RAYPODO confirms the product serial number, hardware configuration, Android version, and back label photo. Please submit the firmware request form before requesting firmware access.


Information Required Before Firmware Is Provided

To request the correct firmware package, please provide the following information to RAYPODO sales or support:

  • Product size
  • CPU model
  • Android version
  • RAM and storage
  • SN number on the back label
  • MAC address, if available
  • Clear photo of the product back label
  • Current issue description
  • Order number, invoice number, or purchase channel, if available

After checking the serial number and product configuration, RAYPODO will provide the correct firmware download link, the required RKDevTool version, and the corresponding upgrade instructions.

To request firmware access, please submit the RAYPODO Firmware Request Form. Our sales or support team will check your product serial number, hardware configuration, Android version, RKDevTool requirement, and back label photo before providing the correct firmware download link.


Common Firmware Upgrade Issues

The device cannot boot after flashing firmware

This may happen if the firmware does not match the product model, screen size, Android version, hardware revision, RKDevTool version, or driver configuration. Please stop using the device and contact RAYPODO support immediately.

The touchscreen, display, Ethernet, or Wi-Fi does not work after upgrade

This may be related to firmware mismatch, LCD panel difference, touch IC difference, Ethernet driver difference, Wi-Fi module difference, production batch difference, or incorrect upgrade tool version. Please provide the product back label photo and firmware file name to RAYPODO support for checking.

The computer cannot detect the device

Install DriverAssistant on the computer first, then confirm that the cable type matches your CPU platform.

RK3288, RK3566, RK3568, and RK3576S devices use a USB-A to USB-A data cable connected to the USB OTG port beside the DC power port. RK3576 and RK3588 devices use a USB-A to USB-C data cable, with the USB-A end connected to the computer and the USB-C end connected to the Type-C port of the device, which is the USB OTG upgrade port on these models.

A charging-only cable cannot transfer data and will not work. Also confirm that the device has entered loader mode, and that the RKDevTool version matches the firmware package before starting the upgrade.

Which USB cable do I need for firmware upgrade?

It depends on the CPU platform. RK3288, RK3566, RK3568, and RK3576S devices need a USB-A to USB-A data cable connected to the USB OTG port beside the DC power port. RK3576 and RK3588 devices need a USB-A to USB-C data cable, with USB-A connected to the computer and USB-C connected to the Type-C port of the device. In all cases the cable must be a data cable. A charging-only cable will not be detected by the upgrade tool.

Can I flash RAYPODO firmware from a Linux computer?

Yes, for selected platforms. The Rockchip Linux Upgrade Tool (upgrade_tool) is a command line tool that can be used on a Linux host, which is useful for automated or production environments. RKDevTool on Windows remains the standard method described in the RAYPODO firmware upgrade SOP. Please contact RAYPODO technical support for the Linux tool and the corresponding command line instructions for your firmware package.

Can I use firmware from another RAYPODO device?

No. Please do not use firmware from another screen size, another CPU platform, another Android version, another order, another production batch, or another RKDevTool instruction without confirmation from RAYPODO sales or support.

Can I use the latest RKDevTool version for all firmware?

No. RKDevTool is not always backward or forward compatible with every firmware package. Some firmware packages require a specific RKDevTool version. Please use the tool version provided by RAYPODO together with the firmware package.

Can I upgrade Android 11 to Android 13 or Android 14 online?

Industrial Android tablets and commercial Android touch panels are different from consumer smartphones. Android version upgrades usually require a dedicated firmware package based on the CPU platform, hardware revision, display panel, touch driver, and system configuration. Please contact RAYPODO before attempting any Android version upgrade.


RAYPODO provides Android PoE tablets, wall mount Android tablets, commercial touchscreen displays, and industrial Android touch panels for fixed installation, embedded systems, digital signage, smart control panels, and 24/7 commercial use.


Need Help?

If your device cannot enter loader mode, cannot be detected by RKDevTool, fails to boot after flashing, or has display, touch, Ethernet, Wi-Fi, or system issues after firmware upgrade, please contact RAYPODO sales or support.

Please include product photos, back label photo, SN number, MAC address, firmware file name, RKDevTool version used, and a short video showing the issue if possible.